LD-200 is a 2 channel 16 bit Digital Signal Processor (DSP) based Inductive vehicle Detector.

LD-200 is a 2 channel 16 bit Digital Signal Processor (DSP) based 
Inductive vehicle Detector.

The primary function of the Detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface.
The switches allow for different loop frequency settings, sensitivity settings, direction logic settings, pulse logic setting and presence logic settings.

Characteristics

• Switches on front panel for selecting various modes.
• Self calibration after switch change.
• Leds on front panel indicating the detectors current operating status and condition.
• To minimize crosstalk between channels, the detector scans the channels sequentially.
• Output signal as "Pulse" or "Presence" for each channel. Output signal is active on detect, leave or delayed.
• Option for direction recognition by using two channels.

Usages

• Traffic detector.
• Commercial, industrial doors and gates.
• Car parks – counting and occupancy.
• Parking bollards.

Technical specifications LD-200
Supply Voltage: 12-24VAC/DC, 110VAC-240 (50Hz) according model.
Power Consumption: 3VA.
Standard Connector: 11 pin 86CP11 or 78S on back side of the detector.
Enclosure: Plastic, IP 30.
Mechanical Dimensions: 77 mm x 76 mm x 42 mm (height, depth, width).
Operating Temperature: (-40 – 70)°C.
Surge Protection: On each Loop isolation transformer and gas discharge tubes.
Inductivity Range: (20 -2000)µH. Ideal (100 - 300) µH with max 30Ω .
Frequency: (20- 100)kHz. Four step switch selectable. Frequency depends on loop size.
Sensitivity: 4 steps switch selectable for each channel.
Output Relay: 3 output relays. Loops and Alarm. Umax = 250Vac, Pmax = 50W.
Output Type: For each channel presence or pulse of 100ms.
Relay output active on detect or on leave. Option for delay of 2 sec .
Indicators: Leds for each channel on front panel for power supply, detection, fault.
Reset: Push button on the front of enclosure.